Power-Bank-50K/120HB(Series)

Home / Products / Hybrid Energy Storage System / Power-Bank-50K/120HB(Series)

Core Advantage

Versatile Scenario Adaptability
Versatile Scenario Adaptability

Versatile Scenario Adaptability

· Diesel Generator Hybrid Operation

· Seamless grid transition in ≤20 ms

· ≤190%(40K) PV Oversizing, Dual PV Inputs

·  ≤150%(50K) PV Oversizing, Dual PV Inputs     

Smart Operation and Maintenance
Smart Operation and Maintenance

Smart Operation and Maintenance

·HMI 10-inch local display

·24/7 monitoring & early warning

·Supports microgrids and diverse application scenarios

Safe and Efficient
Safe and Efficient

Safe and Efficient

· Cycle life ≥ 8,000 cycles

· Multi-level fire protection design

· Intelligent temperature control design
 

Simple and User-Friendly
Simple and User-Friendly

Simple and User-Friendly

· Easy and quick installation

·100 % three-phase imbalance

·Expandable modular design with flexible capacity options
 

Technical Parameters

Power-Bank-50K/120HB(Series)
Power-Bank-50K/120HB(Series)
Power-Bank-50K/120HB(Series)
Power-Bank-50K/120HB(Series)
Power-Bank-50K/120HB(Series)
Power-Bank-50K/120HB(Series)
Power-Bank-50K/120HB(Series)
Power-Bank-50K/120HB(Series)

Power-Bank-50K/120HB(Series)

Specification Models Power-Bank-40K/80HB   Power-Bank-50K/100HB   Power-Bank-50K/120HB

PV Side

Maximum Input Power

76.8kW

Maximum Input Voltage

850 V

Start-up Voltage

250 V

MPPT Operating Voltage Range 200-800 V
Number of MPPT Channels

2

Number of Strings per MPPT Channel 1
Maximum Input Current  64 A  × 2

 

Battery Side

Cell Type

LFP-314 Ah

PACK Series-Parallel Configuration

1P20 S

Number of PACKS

4

5

6

System Capacity

80.38 kWh

100.48 kWh

120.5 kWh

 

 

AC Side

(ON Grid)

Rated Output Power

40 kVA

50 kVA

Rated Output Current 50 A 72.5 A
Maximum Input Current 116 A 145 A

Rated Output Voltage

3P+N+PE,380/400 V

Rated Output Frequency

50/60 Hz(± 5 Hz)
THDi <3%
Power Factor -1~1

AC Side

(OFF Grid)

Rated Output Power

40 kVA

50 kVA

Rated Output Current 58 kVA

72.5 kVA

 
Rated Output Voltage 3P+N+PE,380/400 V
Rated Output Frequency

50/60 Hz

Three-Phase Unbalanced Load Capacity

100 % 

System 

Parameters

Switching Time

≤ 20 ms

Cooling Method

Intelligent Air-Cooled

Protection Rating

lP54

Operating Temperature Range -20 °C ~+ 55 °C (> 45 °C Derating Required)

Humidity Range

0~95 % RH(Non-Condensing)

Altitude

2000 m (>2000 m Derating Required)

Corrosion Resistance Rating

C4

Weight

≈1200 kg

≈1350 kg

≈1500 kg

Fire Protection System

Smoke Detector + Heat Detector + Audible and Visual Alarm + Aerosol Fire Suppression

SOC Calibration Method

Automatic

Dimensions (W × D × H mm)

≈750 × 1300 × 2225 mm

Communication Interface

Ethernet, RS-485

Communication Protocol

Modbus TCP,  Modbus RTU

Cycle Life ≥8000 Cycles(@25 ℃, 0.5P, DOD 90 %, EOL70 %)
System Certification UN38.3; MSDS; IEC62619; IEC63056
PCS Certification IEC62109-1/-2; IEC62477-1; EN50549-1/-10

Projects Cases

Grid-Side Energy Storage

Date

2026.04

Address

ShaYang, HuBei

Projectscale

75MW/150MWh

Application

Using virtual synchronous generator network control technology, it supports island operation, black start, rapid frequency regulation, and dynamic reactive power support; it stores surplus wind and solar power...

Industrial & Commercial User-Side Energy Storage

Date

2024.08

Address

Daojiao, Dongguan

Projectscale

115kW/233kWh 125kW/261kWh

Application

An integrated grid-connected application scenario combining solar power, energy storage, charging, and load management addresses the challenges posed by dispersed solar sites and difficult meter reading...

Industrial & Commercial User-Side Energy Storage

Date

2025.04

Address

TaiShan, JiangMen

Projectscale

1375kW/2871kWh

Application

An independent peak-shaving and valley-filling energy storage grid-connection solution for industrial and commercial applications, powered by the EMS Smart Energy Storage Management Platform...

Microgrid & Off-Grid Energy Storage

Date

2025.10

Address

Laos

Projectscale

125kW/261kWh 125kWp

Application

The annual output of green electricity generated by this system is approximately 187,000 kilowatt-hours, fully replacing power generated by traditional diesel generators. This results in significant annual savings on fuel and consumables...

Grid-Side Energy Storage

Date

2026.04

Address

ShanTong, JingMen

Projectscale

2.5MW/5.01MWh

Application

Power plants can participate in a variety of grid ancillary services, such as peak-off-peak price arbitrage, frequency regulation, voltage regulation, and reserve capacity, thereby establishing a stable and diversified revenue system...

Microgrid & Off-Grid Energy Storage

Date

2025.10

Address

DaFeng, JiangSu

Projectscale

250kW/522kWh 180kWp

Application

To address the challenges faced by remote factories—such as the lack of a reliable power grid, high costs of diesel-powered generators, difficult operation and maintenance, and significant pollution—an off-grid system comprising a 180 kWp photovoltaic array...

400-880-3262

We Value Your Privacy

We use cookies to improve your browsing experience and analyze website traffic. You can choose to accept or reject non-essential cookies.